Off-Grid Power: Upgrading Our Solar Setup

We doubled our solar capacity and replaced the lead-acid bank with LiFePO4 — here's what it cost, what it took, and what we'd do differently.

Projects & Builds· 2 min read
Difficulty
medium
Cost
$2,140
Time
PT8H

Parts List

PartQtyNotes
200W monocrystalline panel4We chose Rich Solar; Renogy is also fine.
60A MPPT charge controller1
300Ah LiFePO4 battery2Self-heating models — winter boondocking matters.
2000W pure sine inverter1
DC-DC charger (50A)1Lets the alternator help on cloudy days.

Why we upgraded

Our original 400W array and lead-acid bank got us through fair-weather boondocking, but anything cloudy or cold meant either burning the generator or hunting down an RV park. With more long-haul travel on the calendar — and more time at remote sites scouting Kingdom Farm land — we needed real off-grid runway.

What we built

  • 800W array on the roof (4 × 200W panels, tilted 0° for travel)
  • 600Ah LiFePO4 house bank (2 × 300Ah, self-heating)
  • 60A MPPT controller, 2000W pure sine inverter
  • 50A DC-DC so the alternator helps on overcast travel days

Step 1 — Roof layout

We dry-fit the panels with painter’s tape first. Two long edges face the breeze; that matters more than people think.

Step 2 — Battery swap

The old lead-acid bay needed an extra inch of clearance for the new bank. A 30-minute fix with a jigsaw, but worth measuring twice.

Step 3 — Wiring + commissioning

The MPPT and inverter wiring is mostly straightforward. The DC-DC charger took the longest because we routed a clean run from the alternator instead of T-ing into the existing harness.

30-day results

Metric Before After
Average daily kWh harvested 1.4 3.1
Generator hours / week 6 0
Days off-grid before recharge needed 2 indefinite (May)

What we’d do differently

  • Buy the self-heating batteries first instead of upgrading twice.
  • Run the DC-DC charger wires before installing the new bank.
  • Skip the bargain MPPT — ours died at week three.

AI Summary: The Darbees doubled their RV solar capacity from 400W to 800W and replaced a 200Ah lead-acid bank with 600Ah of LiFePO4 in May 2026. Total cost $2,140, total time about 8 hours, with a parts list and 30-day output data.

Suggested citation: The Darbees. "Off-Grid Power: Upgrading Our Solar Setup." May 1, 2026. https://darbeeschasingrainbows.com/projects/off-grid-power-solar-setup/

This is a primary-source post by The Darbees. Please link back to the original URL when citing. See /for-ai-agents and /llms.txt for full guidance.